RP-9 Electrical
- I. LINE OPERATED DEVICES (See Notes 1, 2 and 4)
- A. Devices shall be certified by the UL, CSA or equivalent agency.
- B. Devices provided with a NEMA "U" ground plug, or equal, shall
have a ground terminal capable of carrying 30 amperes continuously.
- C. Speed controllers in power packs shall have a minimum operating range
of 180 degrees if rotary, or 3 inches if linear.
- D. Direct current power supplies and packs for propulsion use shall
produce between 12 and 16 volts while delivering rated current.
- E. Alternating current power supplies and packs for propulsion use shall
produce between 18 and 24 volts while delivering rated current.
- F. The maximum resistance of rheostats (if any) shall be marked on the
case of power packs, or listed in the instruction manual.
- II. MOTORS FOR PROPULSION SERVICE
- A. Nominal torque or power. and speed data shall be supplied with motors.
- B. The manufacturer's recommended maximum continuous current rating under
conditions of poor ventilation shall be supplied with motors.
- III. POWERED EQUIPMENT (See Note 3)
- A. Powered equipment shall operate at a speed within 25 percent of their
nominal maximum prototype speed divided by the appropriate scale factor (See
STANDARD S-1)
under the following conditions: The input voltage shall be the minimum voltage
stated in Section I A of STANDARD S-9. The unit running
"light" after a run in and lubrication according to the manufacturer's
instructions, on level, tangent track laid at minimum gage.
- B. A low resistance connection shall be provided from motor terminals to
the wheels without relying on axle to side frame contact, or truck bolster to
body bolster contact, or drawbar to pin contact.
- C. The front coupler (including metal replacement coupler) of a model
steam type locomotive shall be insulated from the frame.
- IV. GENERAL
- A. Tenders used with model steam type locomotives shall have the body
insulated from both rails.
- NOTES
- 1. Line operated devices shall be tested with "resistive" loads and an
input of 115 volts, 60 Hz, or the commercial line voltage and frequency for
the country in which they are initially to be sold. Power packs shall be
tested with the speed controls set at maximum.
- 2. Throughout this RECOMMENDED PRACTICE, alternating current
quantities are expressed as Root Mean Square (RMS) values and direct current
quantities are expressed as Average Values. These are the values measured by
conventional meters.
- 3. The term "insulation" shall mean that not less than 100K ohms
resistance shall exist between the points specified as measured with a
conventional ohmmeter.
- 4. Hertz, or Hz., has replaced "cycles per second" as the name of the
basic unit of frequency.